Connecting Devices to the Chromeleon Server PC
Table: Connecting Dionex Devices

 

HPLC Devices

 

USB

TCP/
IP

10BASE-T DX-LAN

BNC
DX-LAN

RS-232

Other

UltiMate 3000 series (all modules)

X

 

 

 

 

 

UltiMate 3000 RS series (all modules)

X

 

 

 

 

 

UltiMate 3000 series - NCS-3x00

X

 

 

 

 

 

 LPG-3x00 Micro Pump

X

 

 

 

 

 

 UVD-3000¹

X

 

 

 

X

 

 P680

X

X

 

 

 

 

 P580

 

 

 

 

X

 

 AFC-3000

X

 

 

 

X

 

 ASI-100 Series

 

 

 

 

X

 

 GINA 50

 

 

 

 

X

 

 UVD 170U/UVD 340U

X

X

 

 

 

 

 UVD 170S/UVD 340S

 

 

 

 

 

X

 PDA-100 (DX-LAN)

 

 

X

 

 

 

 PDA-100 (USB)

X

 

 

 

 

 

 RF2000

 

 

 

 

X

 

 TCC-100

X

X

 

 

 

 

 STH585

 

 

 

 

X

 

 FAMOS

 

 

 

 

X

 

 UltiMate

 

 

 

 

X

 

 Switchos

 

 

 

 

X

 

 UCI-100/UCI-50

X

X

 

 

 

 

 

¹  Note:  

The UVD-3000 provides an RS-232 port on the rear panel, but it is connected to the USB port on the PC or to another module of the UltiMate 3000 system. To do this, use the RS-232/USB interface cable from the detector's accessories kit.

 

IC Devices

 

USB

TCP/IP

10BASE-T DX-LAN

BNC
DX-LAN

RS-232

Other

 

 

 

 

 

 

 

AS

X

 

 

 

 

 

AS40

 

 

 

 

 

X

AS50 (DX-LAN)

 

 

X

 

 

 

AS50 (USB)

X

 

 

 

 

 

AS-AP

X

 

 

 

 

 

AS-HV²

X

 

 

 

X

 

AXP-AXP/MS²

X

 

 

 

X

 

DX-80

 

X

 

 

 

 

DX-120

 

 

X

 

 

 

DX-500³

 

 

X

 

 

 

DX-600

 

 

X

 

 

 

EG40

 

 

X

 

 

 

EG50

 

 

X

 

 

 

IC20

 

 

 

X

 

 

IC25/IC25A

 

 

X

 

 

 

ICS-90

X

 

 

 

 

 

ICS-900

X

 

 

 

 

 

ICS-1000/1500/2000

X

 

 

 

 

 

ICS-1100/1600/2100

X

 

 

 

 

 

ICS-2500

 

 

X

 

 

 

ICS-3000, ICS-4000,
ICS-5000

X

 

 

 

 

 

 PDA

X

 

 

 

 

 

UI20

 

 

X

 

 

 

VWD

X

 

 

 

 

 

 

²  Note:  

The AS-HV and AXP each have an RS-232 port that provides a connection to a serial port on the Chromeleon PC. If a serial port is not available, you can use the optional RS-232/USB converter (P/N 064261 for the AS-HV; P/N 064590 for the AXP) to connect the device to a USB port on the PC.

³  Note:  

Contact Dionex if you want to control DX-500 devices manufactured in 1994 and/or 1995. For these devices, the CPU needs to be checked.