Dialog Box:
Sequence Wizard: Methods and Reporting

In this step of the Sequence Wizard (see Samples and Sequences  The Sequence Wizard), determine the Chromatographic Methods for all samples.

 

Use Application Template:
(Not available for
Chromeleon Xpress)

Select this check box to use an application template for data acquisition and analysis. See About Application Templates for details about the templates.

When you select this check box (and a suppressor is installed in the system) the Suppressor Type list appears. Select the type of suppressor installed. Note that this selection has no effect on the actual suppressor configuration; the purpose is simply to display a list of application templates for a particular suppressor.

After selecting the suppressor (if any), select the application from the list. The devices configured in the system (pump, detector, eluent generator (if any), and suppressor (if any) determine the applications shown in the list.

If you do not select this check box, you can specify individual programs and quantification methods (see Program and Quantification Method below).

 

 

Program:

Select the Program to be used for processing standard and unknown samples. Click the Browse button to select a program from a different directory. (The Browse button is not available for Chromeleon Xpress.)

When the Sequence is generated, the program selected here is automatically copied to the sequence (specified in Step 5 of the Sequence Wizard).

 Tip: 

Because a copy of the program selected in this field is saved in the sequence, you can change the copied program without affecting the original program, and vice versa.

 

 

Select Additional program files to import (copy) into the new sequence:

(Available for Chromeleon Xpress only)

When this check box is selected, a list of the programs previously created for the system is enabled. Select one or more programs to be copied into the sequence. After you load the sequence into the batch, these programs can be used to run the samples in the sequence. See Chromeleon Xpress: Running Samples

 

 

Quantification Method:
(Not available for
Chromeleon Xpress)

(Optional) Select the method (Quantification Method) to be used for quantitative and qualitative analysis. Click the Browse button to select a method from any directory.

When the sequence is generated, the quantification method selected here is automatically copied to the sequence (specified in Step 5 of the Sequence Wizard).

 Tip: 

Because a copy of the quantification method selected in this field is saved in the sequence, you can change the copied quantification method without affecting the original quantification method, and vice versa.

 

 

Preferred Report:
(Not available for Chromeleon Xpress)

(Optional) If you enter or select a Report, this report definition will automatically be used when opening a sample of the corresponding sequence. In the Batch Report dialog box, this report will be available as the default setting.

To change the Preferred Report, select the corresponding sequence in the Browser and select the Properties command.

 

 

Preferred Channel:
(Not available for Chromeleon Xpress)

(Optional) If you select a preferred channel, this Channel is used as the default in the Browser and is opened by double-clicking a sample. In the Print Report dialog box, this channel will be available as the default setting.

To change the Preferred Channel, select the corresponding sequence in the Browser and select the Properties command.

 

About Application Templates