"Chromatogram" Category
It depends on the detector(s) that is(are) connected which chromatogram variables are available during data acquisition. The table below lists the variables that are available when either a UVD 340 detector or an aQa Mass Spectrometer is connected.
Variable |
Formula |
Description |
Channel Name |
chm.channel |
Shows the channel name. |
Raw Data File Path Name |
chm.rawpath |
See Raw Data |
Number of Peaks |
chm.nPeak |
Shows the number of peaks. |
Select Peak |
chm.peak(OPT) |
Select Peak selects a peak in the chromatogram according to input; opens the Peak Results category |
Count Peaks if ... |
chm.countIF |
Counts the peaks which ... |
Sum Peak Results if ... |
chm.sumIF |
Adds up the characteristics of peaks that .... |
Start Time (relative to Inject Time) |
chm.start_time |
Chromatogram start time [min] |
End Time (relative to Inject Time) |
chm.end_time |
Chromatogram end time [min] |
Signal Value |
chm.sig_value |
Signal value [for example, in mAU] |
Signal Dimension |
chm.sig_dim |
Shows the signal dimension |
Signal Noise |
chm.noise |
Signal noise [for example, in mAU] |
Sample Rate |
chm.sig_step |
Shows the sample rate |
Modified? |
chm.manipulated |
(Yes/no) |
Modification Time |
chm.manip_time |
Corresponding date/time |
Modification Operator |
chm.manip_operator |
Corresponding operator - opens the User Information category |
XXXXX Start Value |
chm.XXXXX |
Start value of the signal parameter XXXXX when acquiring data. |
Delay Time Value |
chm.delayTimeValue |
Delay Time between two detectors |
Delay Time Detector |
chm.delayTimeDetector |
Name of the second detector |
Average |
chm.Average |
Average (for UV channels only) |
Step |
chm.Step |
Step (for UV channels only) |
Wavelength |
chm.Wavelength |
Wavelength (for UV channels only) |
Bandwidth |
chm.Bandwidth |
Bandwidth (for UV channels only) |
RefWavelength |
chm.RefWavelength |
See RefWavelength (Reference Wavelength)) (for UV channels only) |
RefBandwidth |
chm.RefBandwidth |
See RefBandwidth (Reference Bandwidth)) (for UV channels only) |
MassRange |
chm.MassRange |
Mass range of the Mass Spectrometer channel (for MS channels only) |
Polarity |
chm.Polarity |
Polarity (for MS channels only) |
Source Voltage |
chm.Voltage |
Voltage (for MS channels only) |
FilterIndex |
chm.FilterIndex |
Number of the Filter (MS channels only). |
Smoothing |
chm.Smoothing |
Smoothing algorithm (in parenthesis: number of smoothing points) (for MS channels only or if explicitly performed) |