Commands and Tips for Thermo Scientific Devices
Thermo Scientific Surveyor Plus Series: Pump
The following commands and properties are available for the Surveyor Plus pump (please note that the display Filter level determines which commands and properties are displayed).
Also, refer to the information in the manual shipped with the instrument.
General Commands and Properties:
Command/Property |
Description |
Connect |
Connects the instrument to Chromeleon. |
Connected |
Indicates whether the instrument is connected to Chromeleon, that is, under computer control (also, see Connect, Disconnect). |
DegasserStatus |
Indicates the status of the degasser. |
Disconnect |
Disconnects the instrument from Chromeleon. Also see Connect. |
DriverID |
Unambiguous driver name (read-only). |
DriverVersion |
Driver version (read-only). |
FirmwareVersion |
Indicates the firmware version of the instrument (read-only). |
FirmwareVersionConverter |
Indicates the firmware version of the converter board (read-only). |
DriverManufacturer |
Manufacturer of the driver (read-only). |
ModelNo |
Reports the instrument's model number (read-only). |
ModuleManufacturer |
Manufacturer of the hardware module (read-only). |
PumpStatus |
Indicates the status of the pump. |
Ready |
Indicates that the instrument is ready for injection. |
RunTime |
Displays the elapsed method run time. |
SerialNo |
Indicates the serial number of the instrument (read-only). |
Flow and Pressure Commands and Properties:
Command/Property |
Description |
Percentage of each solvent component. |
|
*.Equate |
Name of the component (A, B, C, or D). |
*.Value |
Current value [%] for components A, B, C, or D (read-only). |
ClearError |
Clears the error condition of the pump. |
Compressibility |
Specifies the compressibility of the eluent. |
Sets the flow rate [ml/min]. |
|
*.Nominal |
Reports the nominal flow. |
*.Value |
Reports the current flow (read-only). |
Pressure |
Indicates the pump pressure. |
*.LowerLimit |
Sets the lower pressure limit. The system stops the sample batch and starts emergency handling if the value is outside the set range. |
*.UpperLimit |
Sets the upper pressure limit. The system stops the sample batch and starts emergency handling if the value is outside the set range. |
*.Value |
Current pump pressure (read-only). |
PumpOn PumpOff |
Turns the pump on or off. |
Purge Commands and Properties:
Command/Property |
Description |
Purge |
Starts the purge operation. |
PurgeStop |
Stops the purge operation. |
PurgeTime |
Sets the duration of the purge operation. |
PurgeValve |
Indicates the valve position during the purge operation. |
Commands and Properties Related to Wear Part and Seal Replacement:
Command/Property |
Description |
LeftSealVolume |
Tracks the volume pumped past the left seal. |
MoveToSealReplacement |
Moves the piston to a maintenance position that allows replacement of the seal. The command can only be executed if no method is running. After execution of the command, the pump and any running program is stopped. |
OperationTime |
Tracks the operating time of the pump. |
ResetLeftSealVolume |
Resets the counter for the LeftSealVolume property to 0. Execute this command after replacement of a piston seal. |
ResetRightSealVolume |
Resets the counter for the RightSealVolume property to 0. Execute this command after replacement of a piston seal. |
ResetOperationTime |
Resets the counter for the OperationTime property to 0. Execute this command after replacement of the motor. |
RightSealVolume |
Tracks the volume pumped past the right seal. |
Troubleshooting
The injection is stopped with an Abort message.
The problem occurs when the runtime of the program is set to 1.23 minutes. The reason is an error in the pump's firmware version 3.02.
Solution: Change the run time of the program, for example to 1.22 or 1.24 minutes.
For an example for an emergency program, refer to Thermo Scientific Surveyor Plus Pump: Emergency Program
For information about how to install the instrument, refer to Hardware Installation Thermo Scientific Surveyor Plus LC Pump: Installation.