Commands
and Tips for Thermo Scientific Devices
Vanquish Charger (VCH)
The commands and properties listed below are available for the Vanquish Charger. Some commands and properties may not be visible because a display Filter level was applied.
General
Command/Property |
Description |
AtSafePosition* |
See section on Mover. |
Busy* |
See section on Mover. |
ClearError |
Clears an error. |
ChargerStatus* |
See section on Status. |
Door* |
See section on Mover. |
ErrorState* |
See section on Status. |
FirmwareVersion |
Displays the firmware version of the connected Charger. |
IsPowered |
See section on Mover. |
LightMode |
Determines the behavior of the interior lights of the Charger: On, Off, Dim, Automatic (Dim when door is closed, On when door is open). |
Location |
Displays the location of the swivel arm of the mover. |
MaxTemperature* |
See section on Temperature. |
MinTemperature* |
See section on Temperature. |
Motor* |
See section on Mover. |
OrientationAlert* |
See section on Status. |
PlateOnShovel* |
See section on Mover. |
RackInSampler* |
See section on Status. |
RackInTransfer* |
See section on Status. |
ReadyTempDelta* |
See section on Temperature. |
ResetTemperatureHistory* |
See section on Temperature. |
Save* |
See section on Mover. |
SerialNo |
Displays the serial number of the connected Charger. |
ShelfType |
Displays the installed shelf type as determined by the latest inventory scan. Note: The displayed information can be outdated while an inventory scan is running and will be updated as soon as the inventory scan is finished. Refer to the Operating Manual of the Charger for more information about inventory scans. |
Stop |
Disconnects all motors from the power supply. Consequently, all ongoing movements, for example a running batch, are aborted and pending movements are discarded. |
TempCtrl* |
See section on Temperature. |
Temperature.Actual* |
See section on Temperature. |
Temperature.Error* |
See section on Temperature. |
Temperature.Nominal* |
See section on Temperature. |
TemperatureReady* |
See section on Temperature. |
TriggerInventoryScan* |
See section on Status. |
TemperatureStatus* |
See section on Temperature. |
Status
These properties apply to the mover and inventory configuration.
Property |
Description |
ChargerStatus |
Displays the status of the Charger which is related to the connection state, as well as to the mover state:
|
ErrorState |
Displays the error state of the Charger. Tip: Check the audit trail. |
OrientationAlert |
Note: If a rack/well plate does not have a barcode, or if there is no rack/well plate identified because the shelf level is empty, this property will always be set to Off, even if the rack/well plate is not oriented correctly. |
RackInSampler |
Indicates whether or not one of the racks in the Charger has temporarily been placed into the autosampler due to a pending injection:
|
RackInTransfer |
Indicates if a rack is currently being transferred from the Charger to the autosampler or vice versa: Yes or No. |
TriggerInventoryScan |
Initiates an inventory scan. |
Command |
Description |
AtSafePosition |
Indicates whether the current location of the mover is ‘safe’, i.e. whether one can remove the shelf and rotate the sampler carousel. |
Busy |
Indicates whether the mover is currently in operation. |
Door |
Displays the status of the door. |
IsPowered |
Displays whether the mover motors are powered or not. |
Motor |
Switches the motor power on or off. Note: The motors are switched off automatically when the door is opened. There is no need to power them immediately after the door has been closed, the motors will be re-powered automatically. |
PlateOnShovel |
Indicates whether the mover has a well plate or rack on its shovel. |
Save |
Moves the swivel arm of the mover back to a safe position. |
Stop |
Disconnects all motors from the power supply. Consequently all ongoing movements, for example a running batch, are aborted and pending movements are discarded. |
Command/Property |
Description |
MaxTemperature |
Displays the actual maximum temperature of the Charger after the latest reset of the temperature history. See also ResetTemperatureHistory. |
MinTemperature |
Displays the actual minimum temperature of the Charger after the latest reset of the temperature history. See also ResetTemperatureHistory. |
ReadyTempDelta |
Indicates the maximum allowed deviation between the nominal temperature and the actual temperature. If the actual temperature deviates from the nominal temperature by more than the maximum allowed deviation, the Charger is not ready to operate (TempReady reports NotReady). If set to None, Chromeleon does not check whether the actual temperature deviates from the nominal temperature. |
ResetTemperatureHistory |
Resets the temperature history, so that MinTemperature and MaxTemperature are set to the current temperature. The temperature history logs minimum and maximum temperatures of the Charger since the last reset. |
TempCtrl |
Displays if the temperature control of the Charger is enabled: On, Off. Note: This property can only be set via the TempCtrl property of the autosampler. |
Temperature.Actual |
Displays the actual temperature of the Charger. |
Temperature.Nominal |
Displays the nominal temperature of the Charger. Note: This property can only be set via the Temperature.Nominal property of the autosampler. |
TemperatureError |
Displays whether the thermostatting unit of the Charger is in an error state: Ok, Error. |
TemperatureReady |
Displays whether the thermostatting unit of the Charger is in an equilibrated state. The value depends on ReadyTempDelta. If TempCtrl is Off, TemperatureReady always reports Ready. |
TemperatureStatus |
Displays the status of the thermostatting unit of the Charger: Unknown, Cooling, Heating, AtSetPoint, Error. |
Further Information
Thermo Scientific Vanquish Autosampler: Commands
Thermo Scientific Vanquish Autosampler and Charger: Tips
Thermo Scientific: Commands and Tips.
For information about system wellness and predictive performance of the Charger, refer to Thermo Scientific Vanquish Autosampler: Commands.
For installation details, refer to Hardware Installation: Thermo Scientific Devices:
Thermo Scientific Vanquish Autosampler: Installation
For more information, refer to the Vanquish Charger Operating Manual.