Commands and Tips for Third-Party Devices
Polymer Laboratories ELS 2100 (Ice) / Varian 380-LC (385-LC) ELS Detectors: Commands and Tips
The ELS 2100 and the ELS 380-LC/385-LC drivers support the following commands and properties (please note that the display Filter level determines which commands and properties are displayed):
General commands and tips:
Command/Property |
Description |
Autozero |
Sets the signal output to 10 mV. |
AZ_Done |
Reports the status of an autozero command (Busy or Done). |
ClearDisplayError |
Clears any error messages on the detector's display. |
Connect |
Connects the device to Chromeleon. |
Connected |
Indicates whether the detector is connected to Chromeleon, that is, under computer control (also, see Connect, Disconnect). |
Data_Collection_Rate |
Sets the rate at which Chromeleon collects digital data points from the detector (380-LC/385-LC ELS detectors only). Note: This property must be set directly on the device. |
Disconnect |
Disconnects the detector from Chromeleon and activates manual control from the panel. |
DriverID |
Unambiguous driver name. |
DriverVersion |
Indicates the driver version. |
FirmwareVersion |
Indicates the firmware version. |
Manufacturer |
Indicates the manufacturer of the driver. |
ModelNo |
Indicates the instrument's model number. |
ModelVariant |
Used by Chromeleon to distinguish between the detector variants. |
Ready |
Ready indicates that the device is ready for operation, i.e., no Autozero is started, the temperature has been reached, no error has occurred. |
Standby |
Sets the detector into the Standby mode or cancels this mode (NoStandby). In standby mode, the detector remains connected to Chromeleon.
Run the detector in NoStandby mode for successful data acquisition. |
Device properties:
Command/Property |
Description |
EvaporatorTemperature |
Sets the temperature of the evaporator. Available values: Off, 25° C - 120° C or Off, 10° C - 80° C (ELS 2100 Ice). |
*.Nominal |
Actual evaporator temperature. |
*.Value |
Current evaporator temperature. |
NebuliserTemperature |
Sets the nebulizer temperature. Available values: Off, 25° C - 90° C. |
*.Nominal |
Sets the nominal nebulizer temperature. |
*.Value |
Reports the actual nebulizer temperature. |
CarrierFlow |
Sets the carrier gas flow in [slm]. Available values: 0,90 slm - 3,25 slm. |
*.Nominal |
Sets the nominal carrier gas flow. |
*.Value |
Reports the actual carrier gas flow. |
Channel properties and commands:
Command/Property |
Description |
Starts/ Ends data acquisition |
|
Average |
Averages all measured values. |
Reports the signal's slope, i.e., the difference between the value and the value 1 second ago. |
|
Sets the maximum step rate for Step = Auto; default: 5.1 s. |
|
Retention |
Indicates the retention time for the signal in [ms]. |
Signal |
Indicates the signal value in [mV]. |
Sets the step for data acquisition; |
Special commands:
Command/Property |
Description |
AnalogVoltage |
Analog output voltage that corresponds to the current value . |
LightSourceIntensity |
Sets the light intensity of the diode. Possible values: 1% - 100%. |
PMTGain |
Defines an internal gain factor with which the current value is multiplied. However, this value has no effect on the signal-to-noise-ratio. |
SmoothWidth |
Specifies the number of data points used for data smoothing in the detector. |
For a program example, refer to:
Polymer Laboratories ELS 2100/Varian 380-LC ELS Detector: Program Example.