Installing and Controlling Third-Party Devices
Shimadzu LC-10A, LC-20A and LC-2010 HPLC Systems: Racks
Chromeleon supports different rack types for the Shimadzu autosamplers. Use the Sampler tab page in the Server Configuration program to specify the rack type(s) installed in your autosampler. The SIL-HT and LC-2010 autosamplers can be equipped with two racks.
Type |
Vials/Plates |
Numbering (also, see below) |
Model |
1mL-C |
1 x 175, 1mL vials |
1_1 - 1_175 left rack |
SIL-HTA, |
1.5mL |
1 x 105, 1.5 mL vials |
1_1 - 1_105 left rack |
Only SIL-HTA |
1.5mL-C |
1 x 70, 1.5 mL vials |
1_1 - 1_70 left rack |
Only SIL-HTC |
4mL-C |
1 x 50, 4 mL vials |
1_1 - 1_50 left rack |
SIL-HTA, |
Mtp-C |
2 microtiter plates, |
96: 1_FA1 - 1_BH12 left rack 384: 1_FA1 - 1_BP24 left rack |
SIL-HTA, |
Dwell-C |
2 microtiter plates, |
1_FA1 - 1_BH12 left rack |
SIL-HTA, |
|
|
|
|
Rack 1 (11) |
150 vials |
0-14 |
SIL-10ADvp |
Rack 2 (12) |
70 vials |
0-69 |
SIL-10ADvp |
Rack 3 (13) |
60 vials |
0-59 |
SIL-10ADvp |
Rack 4 (14) |
2 microtiter plates |
1_FA1 - 1_FH12 front rack |
SIL-10ADvp |
Rack 5 (15) |
2 microtiter plates |
1_FA1 - 1_FP24 front rack |
SIL-10ADvp |
Rack 6 (16) |
100 + 3 vials |
0-99 + R101-R103 |
SIL-10ADvp |
Rack 7 (17) |
70 + 3 vials |
0-69 + R101-R103 |
SIL-10ADvp |
|
|
|
|
Rack 1 |
100 vials |
0-99 |
SIL-10AXL, SIL-10A, SIL-10Ai, SIL-10AF |
Rack 2 |
80 vials |
0-79 |
SIL-10AXL, SIL-10A, SIL-10Ai, SIL-10AF |
Rack 3 |
60 vials |
0-59 |
SIL-10AXL, SIL-10A, SIL-10Ai, SIL-10AF |
Rack 4 |
50 vials |
0-49 |
SIL-10AXL, SIL-10A, SIL-10Ai, SIL-10AF |
Rack 5 |
1 microtiter plate |
1_FA1 - 1_FH12 front rack |
SIL-10AXL, SIL-10A, SIL-10Ai, SIL-10AF |
Rack 6 |
2 microtiter plates |
1_FA1 - 1_FH12 front rack |
SIL-10AXL, SIL-10A, SIL-10Ai, SIL-10AF |
Rack 7 |
25 vials |
0-24 |
SIL-10AXL, SIL-10A, SIL-10Ai, SIL-10AF |
Tips:
The autosampler variants for the LC-20A Prominence system provide different rack types for the left and right position (left position: 70 vial rack (same as SIL-HT), right position: 10 vial control rack).
LC-2010 systems use the same rack types as SIL-HT.
Identical rack types have to be used in the left and in the right position (applies to SIL-HT and LC-2010).
One Mtp-C or Dwell-C rack can carry two microtiter plates. Both plates must be of the same type. (If you have installed an Mtp-C rack, use the MTPRack configuration option on the System Controller to specify the number of wells per plate. For more information, refer to the instrument's manual.)
The rack types in brackets (11-17) refer to the versions with temperature control (SIL-10ADvp).
Numbering in the racks for the SIL-HTA and SIL-HTC samplers
175 Vials (1mL-C)
1_25 |
1_50 |
... |
1_175 |
... |
... |
... |
... |
1_3 |
1_28 |
... |
1_153 |
1_2 |
1_27 |
... |
1_152 |
1_1 |
1_26 |
... |
1_151 |
105 Vials (1.5mL)
|
1_30 |
|
... |
|
1_15 |
|
1_45 |
|
1_105 |
|
... |
|
... |
|
... |
|
... |
|
... |
|
1_18 |
|
... |
|
1_3 |
|
1_33 |
|
1_93 |
|
1_17 |
|
... |
|
1_2 |
|
1_32 |
|
1_92 |
|
1_16 |
|
... |
|
1_1 |
|
1_31 |
|
1_91 |
70 Vials (1.5mL-C)
|
1_20 |
|
... |
|
1_10 |
|
1_30 |
|
1_70 |
|
... |
|
... |
|
... |
|
... |
|
... |
|
1_13 |
|
... |
|
1_3 |
|
1_23 |
|
1_63 |
|
1_12 |
|
... |
|
1_2 |
|
1_22 |
|
1_62 |
|
1_11 |
|
... |
|
1_1 |
|
1_21 |
|
1_61 |
50 Vials (4mL-C)
1_10 |
1_20 |
... |
1_50 |
... |
... |
... |
... |
1_3 |
1_28 |
... |
1_153 |
1_2 |
1_27 |
... |
1_152 |
1_1 |
1_11 |
... |
1_41 |
10 Vial Control Rack
1_10 |
... |
1_3 |
1_2 |
1_1 |
384-Well Plate (Mtp-C with 384 wells)
1_FA24 |
1_FB24 |
... |
1_FP24 |
... |
... |
... |
... |
1_FA3 |
1_FB3 |
... |
1_FP3 |
1_FA2 |
1_FB2 |
... |
1_FP2 |
1_FA1 |
1_FB1 |
... |
1_FP1 |
1_BA24 |
1_BB24 |
... |
1_BP24 |
... |
... |
... |
... |
1_BA3 |
1_BB3 |
... |
1_BP3 |
1_BA2 |
1_BB2 |
... |
1_BP2 |
1_BA1 |
1_BB1 |
... |
1_BP1 |
96 (Deep) Well Plate (Dwell-C and Mtp-C with 96 wells)
1_FA12 |
1_FB12 |
... |
1_FH12 |
... |
... |
... |
... |
1_FA3 |
1_FB3 |
... |
1_FH3 |
1_FA2 |
1_FB2 |
... |
1_FH2 |
1_FA1 |
1_FB1 |
... |
1_FH1 |
1_BA12 |
1_BB12 |
... |
1_BH12 |
... |
... |
... |
... |
1_BA3 |
1_BB3 |
... |
1_BH3 |
1_BA2 |
1_BB2 |
... |
1_BH2 |
1_BA1 |
1_BB1 |
... |
1_BH1 |
Note:
For the SIL-10ADvp sampler and SIL-10AXL, Chromeleon uses the same numbering pattern as indicated on the racks.
For information about how to install the Shimadzu LC HPLC Systems, refer to: